Specifications
Input Power
- Model CLT2020-000: 115 VAC ± 10%, 50/60 Hz ± 2 Hz
- Model CLT2020-024: 24 VDC ± 10%
Internal Power Supplies
- 24VDC @ 50ma
- 15VDC @ 100mA
- 10VDC @ 20mA
- 5VDC @ 100mA
Analog Inputs (4)
- 13 bit resolution (12bit +sign)
- Unipolar Mode: 0..+10VDC
- Bipolar Mode: -10..+10VDC
Frequency (High Speed Digital) Inputs (2)
- 50KHz Max, square wave
- Voltage: +15 VDC max
- High Speed Counter capability
Digital Inputs (5)
- 30VDC max
- Sink/Source selectable
Analog Outputs (2)
- 13 bit resolution (12 bit + sign)
- Unipolar Mode: 0..+10VDC
- Bipolar Mode: -10..+10VDC
Relay Outputs (2)
- Form-C contact
- Rated for 3A @ 115 VAC & 30 VDC
Frequency/Digital Outputs (2)
- Isolated Open collector output
- 50KHz Max, square wave
Isolated Communications (4)
- Com A: Modbus® RS422/485 Terminal Strip
- Com B: Modbus® TCP Ethernet
- Com C: Modbus® RS232/422 RJ12
- Com D: USB
General Description • Specifications • Application Examples • Dimensions/Connections