V1000 Standard Features
October 14, 2011V1000 Model Ratings and Dimensions
October 14, 2011V1000 Current Vector Drive by Yaskawa
General Description• Standard Features • Specifications • Model Ratings/Dimensions• Connections
Specifications
Overload Capacity: | 150% Overload for 60 sec. (Heavy Duty)
120% Overload for 60 sec. (Normal Duty) |
Output Frequency: | 0~400 Hz (higher frequencies available with custom software) |
Control Methods: | Open Loop Current Vector Control, V/f Control, PM Open Loop Vector Control
Simple closed loop speed control available |
Protective Design: | IP20/NEMA1 |
Braking Transistor: | Standard in all models |
Braking Torque: | 20 – 40% increase with intelligent high-slip braking function |
KEB Function: | Uses mechanical energy to continue operation during momentary power failure, standard |
Overvoltage Function: | Prevention function for die-cushion in a hydraulic mechanical press and other applications |
Maintenance: | Elapsed timer assists in preventative maintenance for cooling fan, capacitors, and transistors
Easily replaceable cooling fan |
Global Certification: | CE, UL, cUL, RoHS, TUV |
Available I/O: | (7) multi-function digital inputs (1) hardwire baseblock (2) multi-function analog inputs (1) multi-function pulse input (1) multi-function relay output (2) multi-function photo-coupler outputs (1) multi-function 0-10 Vdc analog output (1) multi-function pulse output |
Network Communication: | Standard: RS-422/485 MODBUS 115 kbps
Optional: DeviceNet, EtherNet/IP, Profibus-DP, Modbus TCP/IP, MECHATROLINK-II |
Keypad Operator: |
Standard LED 5 digit display
Optional multi-lingual, full-text remote LCD |
View More Specs and Features
View Brochure
General Description• Standard Features • Specifications • Model Ratings/Dimensions• Connections
Back to AC Drives• Back to Product Line