BLAZER® IV Series
1/4 – 5 HP
Isolated Regen Drives Specifications
General Description • Standard Features • Specifications • Model Ratings/Dimensions • Connections
Specifications
BRC702 Models
- A.C. Input
- 115 VAC ±10%, 50/60 Hz ±2 Hz
- 230 VAC ±10%, 50/60 Hz ±2 Hz
- Armature Output
- 0-90 VDC for 115 VAC input
- 0-180 VDC for 230 VAC input
- Field Output
- 100 VDC @ 1 Amp for 115 VAC input
- 200 VDC @ 1 Amp for 230 VAC input
- Horsepower Range
- 1/4 – 1 HP @ 90 VDC
- 1/2 – 2 HP @ 180 VDC
BRC705 Models
- A.C. Input
- 230 VAC ±10%, 50/60 Hz ±2 Hz
- Armature output
- Field Output
- Horsepower Range
|
All Models
- Speed Regulation
- Armature feedback: ±1.0% of base speed
- Tachometer or Encoder Feedback: ±0.5% of base speed
- Torque Regulation
- ±2% of current range selected
- Adjustments
- Max Speed: -20 to +10% of full base speed
- Current Limit: 0 to 150% of current range selected
- IR Compensation: Range set by current limit jumper
- ACCEL and DECEL: linear, independently adjustable forward and reverse, 2 ranges, 1 – 8 sec. or 8 – 60 sec.
- Jog Speed: 0 – 25% of rated armature voltage
- Sum Trim: 0 – 150% of summing input
- Integral Null: null adjustment to eliminate motor creeping and backup
- Speed Range
- Temperature Range
- 0 – 55ºC for chassis units
- 0 – 40ºC for enclosed units
|
VIEW INSTRUCTION MANUAL
View Brochure
General Description • Standard Features • Specifications • Model Ratings/Dimensions • Connections
Back to DC Drives • Back to Product Line
BLAZER® IV Series
1/4 – 5 HP
Isolated Regenerative Drives