BLAZER® IV Series
1/4 – 5 HP
Isolated Regenerative Drives
General Description • Standard Features • Specifications • Model Ratings/Dimensions • Connections
Standard Features
- Regenerative action provides four quadrant speed control
- Isolation amplifier for providing isolated armature current feedback
- Impedance isolation, 5 Meg Ohms, for armature voltage feedback isolation
- Tachometer and encoder feedback are insensitive to direction of motor rotation
- Encoder power supply, +12 VDC @ 50 mA, terminal strip accessible
- Jog Delay to allow rapid JOG without de-energizing the line contactor to extend contactor life
- Bridge delay circuitry built in to extend contactor life
- Terminal strip access to Accel/Decel output, Velocity Loop output and Current Loop input for systems interface
- Internal jogging pot for adjustment of Jog Speed
- Summing input with on board trim pot to allow voltage summing with speed reference
- Jumper selection to allow summing input to be clamped or not clamped in the Jog Mode
- Jumper selection to control summing input polarity
- 45º angle depluggable terminals for all customer connections except line, armature and field connections
- Terminal strip connections for Forward Run, Reverse Run, Forward Jog, Reverse Jog, Ramp Stop and Emergency Stop
- LED indicators for Power, Forward and Reverse directions
- DCM connector and signal test points for easy troubleshooting
- Inner current loop for fast stable response to load change
- Metal film resistors and cermet pots for temperature stability
|
- I.C. regulated power supplies
- High frequency multi-pulse gating
- Conservative power section rating
- R-C decoupling of signal level inputs for superior noise rejection
- AC line fuses
- Line MOV and snubber for transient protection
- Functional terminal strip labeling and logical P.C. board layout
- Independent adjustable linear acceleration and deceleration in both the forward and reverse directions
- Independent max speed for forward and reverse directions
- Independent current limit for forward and reverse directions
- Integral null adjustment
- Adjustable IR compensation
- Current range selectable by jumper
- Armature, encoder or tachometer feedback selectable by jumper
- Two tachometer feedback voltages selectable by jumper: 7 or 50 VDC per thousand RPM tach feedback
- 300 PPR encoder feedback
- Power On/Off switch for control circuit (enclosed models only)
- Membrane switch control panel for Run Forward, Run Reverse, Jog Forward, Jog Reverse and Ramp Stop. Mushroom style locking button for Emergency Stop (enclosed models with control panel only)
- NEMA 12 enclosure for enclosed models
- Armature contactor and Dynamic Braking for safety disconnect in stopped condition
|
VIEW INSTRUCTION MANUAL
View Brochure
General Description • Standard Features • Specifications • Model Ratings/Dimensions • Connections
Back to DC Drives • Back to Product Line
BLAZER® IV Series
1/4 – 5 HP
Isolated Regen Drives