KBRG Series Standard Features
May 16, 2012KBPC Series Standard Features
May 17, 2012KBPC Series DC Drives by KB Electronics
General Description• Standard Features • Specifications
Specifications
PARAMETER | SPECIFICATION | FACTORY SETTING |
AC Line Voltage Regulation (% Base Speed) | ±0.5 | —– |
Current Ranges (ADC) | 2.5, 5, 7.5, 10 | 10 |
ACCEL and DECEL Ranges (Seconds) | 0.1–15 | 1 |
MIN SPEED Range (% Base Speed) | 0–30 | 0 |
MAX SPEED Range (% Base Speed) | 60–140 | 100 |
IR COMP Range at 115 VAC Line (VDC) | 0–15 | 4 |
IR COMP Range at 230 VAC Line (VDC) | 0-30 | 8 |
CL Range (% Range Setting) | 0–200 | 150 |
TIMED CL Range (Seconds) | 0.5–15 | 7 |
Voltage Following Linearity (% Base Speed) | ± 0.5 | —– |
AC Line Voltage (VAC ± 10%, 50/60 Hz) | 115 or 230 | 230 |
Horsepower Range at 115 VAC Line (Hp) [kw] | 1/50–1, [.015-.75] | —– |
Horsepower Range at 230 VAC Line (Hp) [kw] | 1/25–2, [.03–1.5] | —– |
Armature Voltage Range at 115 VAC Line (VDC) | 0–130* | —– |
Armature Voltage Range at 230 VAC Line (VDC) | 0–220* | 180 |
Field Voltage at 115 VAC Line (VDC) | 100/50** | —– |
Field Voltage at 230 VAC Line (VDC) | 200/100** | —– |
Ambient Temperature Range (°C) | 0–50 | —– |
Speed Range (Ratio) | 50:1 | —– |
Load Regulation, Arm. Feedback(% Base Speed) | ± 1 | —– |
Load Regulation, Tach. Feedback (% Set Speed) | ± 1 | —– |
NOTES: *Maximum recommended output voltage is 90 VDC for 115 VAC and 180 VDC for 230 VAC. Exceeding these output voltages may cause a reduction in load regulation performance.
**For shunt wound motor with lower voltage field, use L1 and F1 connection.
VIEW INSTRUCTION MANUAL
View Data Sheet
For more information about this product,
call 1-888-286-8614 or e-mail us today!
General Description• Standard Features • Specifications
Back to DC Drives• Back to Product Line