Constant Tension Center Wind Control Model D10337-000 Specifications
General Description•Standard Features•Specifications•Application Example•Dimensions/Connections
Specifications
- A.C. INPUT
- 115 VAC, 50/60 Hz, 11VA max., internally fused
- SIGNAL INPUTS
- Line speed signal, isolated, 240 VDC maximum in four ranges
- Winder speed signal, 240 VDC maximum in four ranges
- Diameter signal, +10 VDC maximum
- Tension pot. input, 1K ohm minimum resistance
- Winder armature signal, 90 and 180 VDC ranges
- BUILD RANGE
|
|
- CONTROL RELAYS
- Jog relay, 115 VAC @ .1VA, customer contact required
- Stall tension relay, 115 VAC @ .1 VA, customer contact required
- Memory reset relay, 115 VAC @ .1 VA, customer contact required
- SIGNAL OUTPUTS
- Torque mode: 10 VDC maximum torque reference
- Jog mode: 3 VDC maximum, closed loop speed reference equivelent to 500 RPM motor speed, adjustable
|
VIEW INSTRUCTION MANUAL
View Brochure
General Description•Standard Features•Specifications•Application Example•Dimensions/Connections
Back to System Interface Components • Back to Product Line
Constant Tension Center Wind Control
Model D10337-000 (for constant tension control)