Master Reference Unit
Model D10096-000
General Description • Specifications • Application Examples • Dimensions/Connections
Specifications
A.C. Input
- 115 VAC, ± 10%, 50/60 Hz, internally fused at 1 Amp.
Current Input
- 3 selectable ranges, typical output range is adjustable at 5 to 10 VDC with maximum input.
Input Range
1 to 5 mA
4 to 20 mA
10 to 50 mA
|
Input Impedance
1000 Ohms
270 Ohms
100 Ohms |
Frequency Input
- Accepts a sine or square wave with a peak of 1 to 20 volts, input impedance = 100,000 Ohms, Vout/Fin Range = .0028 to .014, max. output approx. 12 VDC. Max. input frequency = 2,000 Hz.
Potentiometer Input
- +10 VDC, ±10% available to source 2,000 to 10,000 Ohm, 2 Watt pot.
Trim Potentiometer
- Each output section accepts an external 10,000 Ohm, 2 W pot. which allows the master signal to be trimmed from 0 to 100%.
|
|
Voltage Input
- 4 selectable ranges, greater than 1,000,000 Ohms input impedance, max. output voltage approximately 12 VDC.
Input Range
0 to 25 VDC
0.1 to 0.5
0 to 100 VDC
0 to 200 VDC
|
Vout/Vin Range
0.2 to 1.0
0 to 50 VDC
0.05 to 0.25
0.025 to 0.125 |
Accel Output
- A 0 to +10 VDC @ 1 mA signal is available from the Accel/Decel circuit to allow multiple Master Reference Units to be ganged together.
Output
- 4 independent sections with a typical range of 0 to +12 VDC @ 5 mA max.
Accel/Decel Range
- Independently adjustable, linear operation, 2 selectable ranges: 1 to 5 sec. or 4 to 40 sec.
- Note: The Accel/Decel circuit only functions with the potentiometer input.
Linearity
- ±0.5% of 10 VDC span with 100K load.
|
VIEW INSTRUCTION MANUAL
View Brochure
General Description • Specifications • Application Examples • Dimensions/Connections