Electrical
Input Voltage
4.75 to 28 VDC max for temperatures up to 70° C
4.75 to 24 VDC for temperatures between 70° C to 100° C
Input Current
100 mA max with no output load
Input Ripple
100 mV peak-to-peak at 0 to 100 kHz
Output Format
Incremental – Two square waves in quadrature with channel A leading B for clockwise shaft rotation, as viewed from the mounting face.
Output Type
Line Driver – 20 mA max per channel (Meets RS 422 at 5 VDC supply)
Index
Once per revolution.
0475 to 4096 CPR: Gated to output A
0001 to 0474 CPR: Ungated
Max Frequency
200 kHz
Noise Immunity
Tested to BS EN61000-4-2; IEC801-3; BS EN61000-4-4; DDENV 50141; DDENV 50204 BS EN55022 (with European compliance option); BS EN61000-6-2; BS EN50081-2
Symmetry
180° (±18°) electrical
Quad. Phasing
90° (±22.5°) electrical
Min. Edge Sep
67.5° electrical
Rise Time
Less than 1 microsecond
Mechanical
Max. Shaft Speed
6000 Rpm. Higher shaft speeds may be achievable, contact customer service.
Bore Size
0.625″, 0.750″, 0.875″, 1.000″, 14 mm, 19mm, and 24mm
Bore Tolerance
+0.0015″/-0.000″
User Shaft Tolerances
Radial Runout
0.005″
Axial Endplay
±0.015″
Moment of Inertia
3.3 x 10-³ oz-in-sec² typical
Electrical Conn
Terminal Strip in conduit box.
Housing
All metal construction.
Mounting
NEMA 56C to 184C
Environmental
Operating Temp
0° to 70° C for standard models
0° to 100° C for high temperature option
Storage Temp
-25° to 100° C
Humidity
98% RH non-condensing
Vibration
10 g @ 58 to 500 Hz
Shock
50 g @ 11 ms duration
Sealing
IP65 for Option A housing style with gasket kit
IP50 for Option B housing style
|