Sonictrac® Measuring Unit (distance measurement tool)
Model SMU100-XXX
General Description•Standard Features•Specifications•Application Example•Dimensions/Connections
Specifications
A.C. INPUT
- 115 VAC, 50/60 Hz,1 phase fused at .3 amperes
SIGNAL INPUTS
- +10 VDC maximum with 10K ohms input impedance
- External CTL-CLK input, 7 Hz, 50% duty at 5 volts peak maximum for simultaneous “slave” operation as second Sonictrac® Measuring Unit without interference or cross-talk
SIGNAL OUTPUTS
- Positive and negative 10 VDC supplies at 2 mA maximum each (5K to 1 OK ohm load impedance)
- Inverted CTL-CLK output – 7 Hz, 50% duty at 1 mA maximum – for “slave” operation of a second Sonictrac®
- D.C. Voltage output, variable based on distance, +10 volts maximum at 10 mA maximum. Resolution to 1/4096 of full scale output possible
|
|
RELAY OUTPUT
- Fault relay – form “C” contact output, 120 VAC at .2 amps inductive or .5 amps resistive load DISPLAY
- 3 digit LED display of distance with .1 foot resolution
RANGE
- The LED display will constantly indicate measured distances up to 35 feet regardless of selected range.
- Digital-to-Analog conversion occurs within a distance from 1/2 to 30 feet. This distance is divided into the following four ranges: 1/2 to 5 feet, 1/2 to 10 feet, 1/2 to 20 feet, 1/2 to 30 feet
SCAN RATE
- Cycles occur at 7 Hz or once every 143 millisec.
|
VIEW INSTRUCTION MANUAL
View Brochure
General Description•Standard Features•Specifications•Application Example•Dimensions/Connections
Back to System Interface Components • Back to Product Line
Sonictrac® Measuring Unit (distance measurement tool)
Model SMU100-XXX